DRAM Detective · Case File 0.8
The Label, the Ruler, and the Subtraction
Timing numbers have three origins — copy the label, measure with the ruler, subtract the gap.
Some numbers are stamped at the factory…
the label = copy · the ruler = measure · the subtraction = two numbers
the label — stamped at the factory, copied at power-up
SPD (the nameplate)
tCL · tRCD · tRP
tWR · tRFC · tREFI
copy
controller
the die's own physics — read once, never touched again
doesn't depend on the board
the ruler — measured on-site, every board is different
the board's trace
the tape measure
DQS delay
Vref · RTT
DFE taps
training drives traffic and measures, one value at a time
trace length · temperature · voltage — all vary
the subtraction — two numbers, no ruler reads the gap
max
−
min
=
delta
the gap between two ranks' timing — no register holds it
subtract the two trained numbers, add a tCCD baseline + guardband
= the turnaround (Case 1.13)
‹ Back
Next ›
Step 1 of 3
Copy the label, measure with the ruler, subtract the gap — training always turns the ruler.